Palo Alto Networks, Inc. is a network and enterprise security company based in Santa Clara, California. The company’s core products are a platform that includes advanced firewalls designed to provide network security, visibility, and granular control of network activity based on application, user, and content identification and cloud-based offerings that extend those firewalls to cover other aspects of security. In 2017, Palo Alto Networks announced the availability of its new cloud-based service Logging Services, allowing customers to amass their own data.
for this Monitor Temperature, Fan speed Must enable ENTITY-SENSOR-MIB.mib

This is lab specialist for palo Alto PA-3000 / PA-3020
OID PA-3020 = OID PA-5050 =OID PA Firewall

1. Info Hardware Temperature & Fan

info OID Hardware : 1.3.6.1.2.1.47.1.1.1.1.7

[root@TeguhLab ~]# snmpwalk -v2c -c  teguht 10.10.10.10 1.3.6.1.2.1.47.1.1.1.1.7
SNMPv2-SMI::mib-2.47.1.1.1.1.7.1 = STRING: "PA-3020"
SNMPv2-SMI::mib-2.47.1.1.1.1.7.2 = STRING: "Fan #1 RPM"
SNMPv2-SMI::mib-2.47.1.1.1.1.7.3 = STRING: "Fan #2 RPM"
SNMPv2-SMI::mib-2.47.1.1.1.1.7.4 = STRING: "Fan #3 RPM"
SNMPv2-SMI::mib-2.47.1.1.1.1.7.5 = STRING: "Fan #4 RPM"
SNMPv2-SMI::mib-2.47.1.1.1.1.7.6 = STRING: "Temperature @ Ocelot"
SNMPv2-SMI::mib-2.47.1.1.1.1.7.7 = STRING: "Temperature @ Switch"
SNMPv2-SMI::mib-2.47.1.1.1.1.7.8 = STRING: "Temperature @ Cavium"
SNMPv2-SMI::mib-2.47.1.1.1.1.7.9 = STRING: "Temperature @ Intel PHY"
SNMPv2-SMI::mib-2.47.1.1.1.1.7.10 = STRING: "Temperature @ Switch Core"
SNMPv2-SMI::mib-2.47.1.1.1.1.7.11 = STRING: "Temperature @ Cavium Core"
[root@TeguhLab ~]#


Resume Info Hardware Temperature & Fan
1.3.6.1.2.1.47.1.1.1.1.7.2 Fan #1 RPM
1.3.6.1.2.1.47.1.1.1.1.7.3 Fan #2 RPM
1.3.6.1.2.1.47.1.1.1.1.7.4 Fan #3 RPM
1.3.6.1.2.1.47.1.1.1.1.7.5 Fan #4 RPM
1.3.6.1.2.1.47.1.1.1.1.7.6 Temperature @ Ocelot
1.3.6.1.2.1.47.1.1.1.1.7.7 Temperature @ Switch
1.3.6.1.2.1.47.1.1.1.1.7.8 Temperature @ Cavium
1.3.6.1.2.1.47.1.1.1.1.7.9 Temperature @ Intel PHY
1.3.6.1.2.1.47.1.1.1.1.7.10 Temperature @ Switch Core
1.3.6.1.2.1.47.1.1.1.1.7.11 Temperature @ Cavium Core

2. Info Output for temperature & Fan Speed
info OID Output : 1.3.6.1.2.1.99.1.1.1.4

[root@TeguhLab ~]# snmpwalk -v2c -c teguht 10.10.10.10  1.3.6.1.2.1.99.1.1.1.4
SNMPv2-SMI::mib-2.99.1.1.1.4.2 = INTEGER: 14310
SNMPv2-SMI::mib-2.99.1.1.1.4.3 = INTEGER: 14781
SNMPv2-SMI::mib-2.99.1.1.1.4.4 = INTEGER: 14362
SNMPv2-SMI::mib-2.99.1.1.1.4.5 = INTEGER: 14838
SNMPv2-SMI::mib-2.99.1.1.1.4.6 = INTEGER: 29
SNMPv2-SMI::mib-2.99.1.1.1.4.7 = INTEGER: 34
SNMPv2-SMI::mib-2.99.1.1.1.4.8 = INTEGER: 34
SNMPv2-SMI::mib-2.99.1.1.1.4.9 = INTEGER: 24
SNMPv2-SMI::mib-2.99.1.1.1.4.10 = INTEGER: 52
SNMPv2-SMI::mib-2.99.1.1.1.4.11 = INTEGER: 45
[root@TeguhLab ~]#

sample Info Output for temperature & Fan Speed
1.3.6.1.2.1.99.1.1.1.4.2 Fan #1 RPM
1.3.6.1.2.1.99.1.1.1.4.3 Fan #2 RPM
1.3.6.1.2.1.99.1.1.1.4.4 Fan #3 RPM
1.3.6.1.2.1.99.1.1.1.4.5 Fan #4 RPM
1.3.6.1.2.1.99.1.1.1.4.6 Temperature @ Ocelot
1.3.6.1.2.1.99.1.1.1.4.7 Temperature @ Switch
1.3.6.1.2.1.99.1.1.1.4.8 Temperature @ Cavium
1.3.6.1.2.1.99.1.1.1.4.9 Temperature @ Intel PHY
1.3.6.1.2.1.99.1.1.1.4.10 Temperature @ Switch Core
1.3.6.1.2.1.99.1.1.1.4.11 Temperature @ Cavium Core

3. info Temperature & Fan status

[root@TeguhLab data]# snmpwalk -v2c -c  teguht 10.10.10.10 1.3.6.1.2.1.99.1.1.1.5
SNMPv2-SMI::mib-2.99.1.1.1.5.2 = INTEGER: 1
SNMPv2-SMI::mib-2.99.1.1.1.5.3 = INTEGER: 1
SNMPv2-SMI::mib-2.99.1.1.1.5.4 = INTEGER: 1
SNMPv2-SMI::mib-2.99.1.1.1.5.5 = INTEGER: 1
SNMPv2-SMI::mib-2.99.1.1.1.5.6 = INTEGER: 1
SNMPv2-SMI::mib-2.99.1.1.1.5.7 = INTEGER: 1
SNMPv2-SMI::mib-2.99.1.1.1.5.8 = INTEGER: 1
SNMPv2-SMI::mib-2.99.1.1.1.5.9 = INTEGER: 1
SNMPv2-SMI::mib-2.99.1.1.1.5.10 = INTEGER: 1
SNMPv2-SMI::mib-2.99.1.1.1.5.11 = INTEGER: 1
[root@TeguhLab data]#

sample Info Temperature & Fan status
1.3.6.1.2.1.99.1.1.1.5.2 Fan #1 RPM
1.3.6.1.2.1.99.1.1.1.5.3 Fan #2 RPM
1.3.6.1.2.1.99.1.1.1.5.4 Fan #3 RPM
1.3.6.1.2.1.99.1.1.1.5.5 Fan #4 RPM
1.3.6.1.2.1.99.1.1.1.5.6 Temperature @ Ocelot
1.3.6.1.2.1.99.1.1.1.5.7 Temperature @ Switch
1.3.6.1.2.1.99.1.1.1.5.8 Temperature @ Cavium
1.3.6.1.2.1.99.1.1.1.5.9 Temperature @ Intel PHY
1.3.6.1.2.1.99.1.1.1.5.10 Temperature @ Switch Core
1.3.6.1.2.1.99.1.1.1.5.11 Temperature @ Cavium Core

4. Info Unit String temperature & Fan Speed

info OID Unit : 1.3.6.1.2.1.99.1.1.1.6

[root@TeguhLab ~]# snmpwalk -v2c -c teguht 10.10.10.10  1.3.6.1.2.1.99.1.1.1.6
SNMPv2-SMI::mib-2.99.1.1.1.6.2 = STRING: "rpm"
SNMPv2-SMI::mib-2.99.1.1.1.6.3 = STRING: "rpm"
SNMPv2-SMI::mib-2.99.1.1.1.6.4 = STRING: "rpm"
SNMPv2-SMI::mib-2.99.1.1.1.6.5 = STRING: "rpm"
SNMPv2-SMI::mib-2.99.1.1.1.6.6 = STRING: "(C)"
SNMPv2-SMI::mib-2.99.1.1.1.6.7 = STRING: "(C)"
SNMPv2-SMI::mib-2.99.1.1.1.6.8 = STRING: "(C)"
SNMPv2-SMI::mib-2.99.1.1.1.6.9 = STRING: "(C)"
SNMPv2-SMI::mib-2.99.1.1.1.6.10 = STRING: "(C)"
SNMPv2-SMI::mib-2.99.1.1.1.6.11 = STRING: "(C)"
[root@TeguhLab ~]#

sample Info Unit String temperature & Fan Speed
1.3.6.1.2.1.99.1.1.1.6.2 Fan #1 RPM
1.3.6.1.2.1.99.1.1.1.6.3 Fan #2 RPM
1.3.6.1.2.1.99.1.1.1.6.4 Fan #3 RPM
1.3.6.1.2.1.99.1.1.1.6.5 Fan #4 RPM
1.3.6.1.2.1.99.1.1.1.6.6 Temperature @ Ocelot
1.3.6.1.2.1.99.1.1.1.6.7 Temperature @ Switch
1.3.6.1.2.1.99.1.1.1.6.8 Temperature @ Cavium
1.3.6.1.2.1.99.1.1.1.6.9 Temperature @ Intel PHY
1.3.6.1.2.1.99.1.1.1.6.10 Temperature @ Switch Core
1.3.6.1.2.1.99.1.1.1.6.11 Temperature @ Cavium Core

5. Resume Table information about grafik & oid Temperature, Fan Speed

6. Monitoring Temperature on NMS(Example Infosim Stablenet & PRTG)
Infosim Stablenet
PRTG



7. Monitoring Fan Speed on NMS(Example Infosim Stablenet & PRTG)
Infosim Stablenet

PRTG

for monitoring OID, used SNMP Custom on PRTG

sample link
https://live.paloaltonetworks.com/t5/Learning-Articles/What-is-the-SNMP-OID-for-monitoring-internal-temperature-or-CPU/ta-p/61570
https://live.paloaltonetworks.com/t5/Management-Articles/SNMP-for-Monitoring-Palo-Alto-Networks-Devices/ta-p/61052
https://live.paloaltonetworks.com/t5/Configuration-Articles/How-to-Configure-SNMPv2-on-the-Palo-Alto-Networks-Firewall/ta-p/61318
https://www.paloaltonetworks.com/documentation/misc/snmp-mibs.html

No comments: